           Products  Fluorescence Spectrophotometers  F-7100
 

 

 


Fluorescence Spectrophotometer F-7100

Research grade, high sensitivity fluorescence spectrophotometer. The Hitachi F7100 features the highest sensitivity in its class and an extremely long lifetime light source as well as high speed scanning and a host of accessories.

 

  
   
FL33 ETHANOL MEASUREMENT AND ENZYME ASSAY WITH USE OF AUTOMATIC 4-TURRET ACCESSORY

The F-7000 fluorescence spectrophotometer achieves a high sensitivity (S/N 800:RMS), ultra-high-speed (60,000nm/min) wavelength scan at the highest level in its class, with a wide dynamic range up to 6 digits. Furthermore, it is applied to research, development, and quality control in a broad range of fields, such as industrial materials, life sciences, and biotechnology.
The 4-turret accessory used in this experiment automatically measures, by computer control, the time course of the fluorescence intensity at regular time intervals through 4 rotating cells installed in a turret. A reaction trace for an enzyme is used to measure the time course of fluorescence intensity in plural samples. Previously, the time course was measured for one sample at a time, so the measurement time required was proportional to the number of samples. Application of the automatic 4-turret accessory reduces measurement time.
An enzyme assay was applied to ethanol measurement in this experiment. The amount of ethanol in the fish is increased according to a decline of the freshness, so this measurement is referred to as the freshness index. Ethanol is usually measured with a spectrophotometer. When ethanol is present in trace amounts,
a low concentration measurement is performed with a fluorescence spectrophotometer. In this experiment, the general enzyme assay reagent "F-kit ethanol (J.K.International)" was used. In addition to the enzyme assay, a spectrophotometer was used to measure ethanol amounts. The analysis conditions were optimized, and an analytical curve for a standard solution was created.
   
FL32 FLUORESCENCE SPECTRUM MEASUREMENT METHOD ALLOWING A COMPARISON OF DIFFERENT EQUIPMENT - SPECTRAL CALIBRATION OF INSTRUMENTAL RESPONSE AND VALIDATION METHOD, AND MEASUREMENT EXAMPLE FOR A STANDARD FLUORESCENT MATERIAL

Keywords: Fluorescence spectrum, Spectrum calibration, Instrumental response, Rhodamine B, Quinine sulfate, Standard material, GLP/GMP program
 
    TEL: 0208-0903462          FAX: 0208-1506737           EMAIL: sales@lambda-at.com
 
UV VIS
Fluorescence
ICP
Mercury Analysers
TOC
AAS
 
 

Hitachi

Hitachi

Teledyne Leeman Labs

Teledyne Leeman Labs

Teledyne Tekmar

Hitachi

 
  U5100
U5300
U2900/2910
U3900
U3900H
U4150
DropScan


F2700
F2710
F7100
Prodigy 7
Prodigy Plus
Prodigy Glove Box
Prodigy Mobile

QuickTrace® M-7600
QuickTrace® M-8000
Hydra IIC

Lotix
Torch
Fusion
ZA3000 Series  
Solid Sample Analysis
Prodigy DC Arc

 

 
Pressure Digestion
Reaction Vessels
Elemental Analysis
Water Determination
Microwave Digestion
Inficon
 
 

Berghof

Berghof

TSHR

Berghof

Berghof

 ---  
  DAB BR TX 1800
TX 6000
TS 6000
TN 6000
TX 7000
TS 7000
TN 7000
HR 7000
FU 3


EasyH2O®